x|act ci |
ceramic sensor (flush) hygienical application |
|
The precise pressure transmitter x|act ci measures the pressure of gases, steam and fluids. The special-developed capacitive ceramic sensor for this transmitter, which can optionally be delivered in pure ceramic, has a high overpressure capability and excellent media stability. |
|
Several process connections e.g. inch thread or hygienic versions like Varivent, dairy pipe or Clamp are available. The robust stainless steel globe housing has a high ingress protection IP 67 and all characteristics for a residue-free and antibacterial cleaning. |
Features |
nominal pressure: 0 … 160 mbar up to 0 … 20 bar |
|
accuracy: 0.1 % FSO |
|
turn-down 1:5 |
|
with integrated display and operating module |
|
diaphragm ceramics Al2O3 (99.9 %) |
|
flush mounted, capacitive ceramic sensor |
|
hygienic version |
|
several process connections (inch thread, Clamp, etc.) |
Optional Features |
explosion protection intrinsic safety (ia) |
|
HART®-communication |