EE300Ex | Humidity and temperature transmitter for intrinsically safe applications |
The EE300Ex humidity and temperature transmitter is dedicated for measurement in explosion hazard areas. It complies with the classifications for Europe (ATEX), International (IECEx) and USA / Canada (FM) and can be employed in gas and dust explosion hazard areas. The intrinsically safe EE300Ex can be installed in the explosion hazard area even in zones 0 / 20 (Divison 1). | |
Type | EE300Ex Intrinsically Safe Humidity / Temperature Transmitter with remote sensor probe |
EE300Ex Intrinsically Safe Humidity / Temperature Transmitter for wall mounting | |
Detail | The 2-part enclosure facilitates easy installation and dismounting for calibration without time-consuming wiring. The robust and easy-to-clean stainless steel housing is optimized for the pharmaceutical and chemical industries. The well proven E+E humidity sensor technology grants reliable, long-term stable measurements in challenging applications. |
Besides measurement of relative humidity and temperature, the EE300Ex calculates all humidity related parameters, such as dew-point temperature [Td], wet-bulb temperature [Tw], absolute humidity [dv], etc. The intrinsically safe humidity and temperature transmitter features two 4-20 mA outputs in 2-wire technology. | |
Moisture in oil measurement | In the same way as humidity measurement in air, the EE300Ex is appropriate for moisture in oil measurement. The moisture content of oil can be issued absolute as water content in [ppm] or relative as water activity [aw]. Typical applications for moisture in oil measurement are found in systems for cleaning/drying oil or on oil platforms for online monitoring of lubrication and gear oils. |
Typical applications | Chemical industry |
Pharmaceutical industry | |
Painting cabinets | |
Explosion hazard storage rooms | |
Power stations | |
Grain mills | |
Oil platforms | |
Moisture in oil measurement | |
Key Features EE33 | For gas and dust applications |
Direct mounting in zones 0 / 20 | |
All humidity related physical quantities | |
Best precision up to 180°C (356 °F) | |
Pressure-tight up to 300 bar (4351 psi) | |
Wall mount or remote probe versions | |
Water content and water activity in oil | |
Technical data EE33 | |
MEASURING RANGE | 0-100% RH |
-40…180 °C (-40…356 °F) | |
ACCURACY | ±1.3% RH |
±0.2 °C (±0.36 °F) | |
PRESSURE RANGE | 0.01…300 bar (0.15…4351 psi) |
OUTPUTS | 4-20 mA (2-wire) |
SUPPLY | 24 V DC |