Features
High accuracy | Accuracy is within ±0.5% | |
Fluid is directly measured by gear or roots, enabling accurate measuring. | ||
Compact design | The flowmeter is compactly designed, yet the indicator is easy to read. | |
Excellent durability | Simple structure enables long term durability with virtually no degradation of accuracy. |
Specifications
Size : 80mm (3B)~100mm (4B) | Suitable for large volume flow between 0.6~130m³/h | |
Employs roots rotors made of cast iron | ||
Roots rotors rotate without physical contact – Extremely low pressure loss – Accuracy remains unchanged over a long period of time |
||
Accuracy | ±0.5% | |
Flow Range | Refer to next page | |
Max. Working Pressure | 1MPa | |
Hydraulic Test Pressure | 2MPa | |
Size 1/2B | ||
–Kerosene, diesel/light oil, A heavy oil : 80℃ Size 3/4B & 1B : | ||
Max. Working Temperature | –Kerosene, diesel/light oil, : 80℃ | |
Body | ||
Flange Rating | JIS10K FF | |
Body | Size1/2 B : FC250 (Cast iron) Size 3/4B & 1B : FCD400 (Ductile iron) | |
Material | Rotor | Size1/2B : Phenol resin Size3/4B & 1B : PPS resin |
04X : Totalizing counter (7 digits), Reset counter (5 digits) | ||
Counter Unit | 02X : Totalizing counter (7 digits) | |
Transmitter | Reed switch (02S, 04S) | |
Electrical Transmitter Unit | Output Pulse | Max. 10Hz |
Contact Life Time | 10 million times | |
Cable | Double core shield cable | |
Flow Direction | Right → Left (Standard) | |
Painting Color | Munsell 1.4PB 3.1/1.2 |