Highly accurate and reliable turbine meter by the original fluid balance structure through the use of back pressure has been extensively improved in its function by adopting intelligent display unit having communication function.
Features
Compact design
Multifunctional because of electronic and compact design.
Measurement with high accuracy
Liniarization function compensates instrumental errors at any flow point as close to zero as possible. In addition, temperature compensation can be made by connection with the resistance temperature sensor, and it allows highly accurate measurements and control.
Multi-functionalization
Display items can be selected from totalized volume, instantaneous flow (compensated / non-compensated value), temperature etc.
Standard specification
Turbine meter
Accuracy | ±0.2%, ±0.5% | |
Connection size | 3/4B (20 mm) ~ 14B (350 mm) | |
Flange rating | JIS 10K, 20K, JPI, ASME Class 150, 300 | |
Max. Working pressure | Depends on the flange rating | |
Fluid temperature | -10~80℃ | |
Material | Housing | SUS304 |
Blade | SUS631 or 430 | |
Bearing | Tungsten carbide |
Display unit
Functions | * Linearization; 4-line segments (5 points), ±0.005% * Temperature compensation; Compensation range -50~150℃, ±0.075% Coefficient compensation; Compensation of instrumentation error change of flowmeter * Compensation of instrumental error of resistance temperature sensor; 2-line segments (3 points) |
Display | LCD Totalizing counter, Reset counter Instaneous flow; Max.7 digits Temperature display; Max. 5 digits (if temperature input is available) |
Output | Pulse output, Analog output |
Communication | SMART communication |