EE8915 |
CO2 Sensor for Railway Applications |
|
EE8915 measures reliably CO2 concentration in harsh environment and complies with the relevant railway standards. Active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independent of temperature, altitude or weather conditions. |
Type |
EE8915 CO2 sensor for duct mounting with polycarbonate enclosureEE8915 CO2 sensor for duct mounting with polycarbonate enclosure |
|
EE8915 CO2 sensor for wall mounting with polycarbonate enclosureEE8915 CO2 sensor for wall mounting with polycarbonate enclosure |
Detail |
The EE8915 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long-term stability. A multi-point CO2 and temperature adjustment procedure leads to excellent measurement accuracy over the entire temperature working range. |
|
The innovative design enables the combination of short response time and high protection class. The CO2 measured data is available simultaneously as voltage and current output signal. The free EE-PCS Product Configuration Software facilitates the configuration and adjustment of the EE8915. |
|
Due to the compliance with the tough railway standards, the EE8915 stands for excellent performance in any challenging process and climate control application. |
Compliance with railway standards |
EN50155:2017- Electronic equipment used on rolling stock |
|
EN50121-1:2017 – Electromagnetic compatibility – general |
|
EN50121-3-2:2016 – Electromagnetic compatibility – rolling stock |
|
EN61373:2010 – Rolling stock equipment – shock and vibration tests |
|
EN50125-1 – Environmental conditions for equipment – rolling stock and on-board equipment |
|
EN45545-2 – Fire protection on railway vehicles |
|
EN50306 – Railway rolling stock cables having special fire performance |
Key Features EE8915 |
E+E dual wavelength NDIR working principle |
|
T and p compensation with on-board sensors |
|
IP65 protection class |
|
Short response time |
|
Excellent long-term stability |
|
High insensitivity to pollution |
|
Voltage and current outputs |
|
User configurable and adjustable |
Technical data EE8915 |
|
MEASURING RANGE |
0…2000 ppm |
|
0…5000 ppm |
|
0…10000 ppm |
ACCURACY – *MV – MEASURED VALUE |
< ± (50 ppm +2% of mv*) |
|
< ± (50 ppm +3% of mv*) |
|
< ± (100 ppm +5% of mv*) |
OUTPUTS |
0-5 / 10V and 0 / 4-20mA |
SUPPLY |
10-35 V DC |