EE872

EE872 EE872 Modular 4 in 1 probe for CO2, humidity, temperature and pressure
  The EE872 reliably measures CO2 concentration up to 5 % (50 000 ppm) in agriculture, life stock barns, hatchers, incubators, green houses or outdoors. The active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independently of the altitude or environmental conditions.
Type

EE872 CO2 probe plug with polycarbonate enclosure

  EE872 CO2 probe plug with stainless steel enclosure
Detail EE872 incorporates the E+E dual wavelength NDIR CO2 sensor, which automatically compensates for ageing effects, is highly insensitive to pollution and ensures an outstanding long term stability. The multi-point CO2 and temperature adjustment leads to an outstanding measurement accuracy. The RH sensing element with E+E proprietary coating is suitable even for aggressive and corrosive environment.
  Beside CO2, the EE872 measures also relative humidity (RH), temperature and ambient pressure (p). Additionally, the devices calculated also the dew point temperature (Td).
  The heated versions of the EE872 are suitable even for high humidity and condensing environment. The IP65 enclosure and the PTFE filter cap offer excellent protection in polluted environment. With a catalytic filter cap, the EE872 is also appropriate for applications with periodical H2O2 sterilization.
  The CO2 measured data is available simultaneously on the analogue voltage and current outputs. Depending on the EE872 version, the RS485 interface with Modbus RTU protocol offers also the RH, T, p, or Td data.
  The free EE-PCS Product Configuration Software together with an optional adapter cable facilitates the configuration and adjustment of the EE872.
Key Features EE872 4 in 1: CO2, RH, T and p measurement
  Heated versions for high humidity, condensing conditions
  Dual wavelength NDIR CO2 measuring principle
  CO2 measuring range up to 50,000 ppm
  T and p compensation with on-board sensors
  Replaceable sensing module
  IP65 protection class
  Low power consumption
  Excellent long-term stability
  High insensitivity to pollution
  Analogue output or Modbus RTU
  User configurable and adjustable
Technical data EE872  
MEASURING RANGE CO2 0…2000 ppm
  0…5000 ppm
  0…10000 ppm
  0…3 % (30000 ppm)
  0…5 % (50000 ppm)
ACCURACY CO2 – * MV – MEASURED VALUE ± (50 ppm + 2 % mv*)
  ± (50 ppm + 3 % mv*)
  ± (100 ppm + 5 % mv*)
  ± (1.5 % from full scale + 2 % mv*)
  ± (1.5 % from full scale + 2 % mv*)
MEASURING RANGE RELATIVE HUMIDITY 0…95 % RH (non condensing)
ACCURACY RELATIVE HUMIDITY AT 25 °C (77 °C) AND 20…80% RH typ. ± 3 % RH
MEASURING RANGE PRESSURE 700…1100 mbar (10.15…15.95 psi)
ACCURACY PRESSURE AT 25 °C typ. ± 2 mbar
MEASURING RANGE TEMPERATURE -40…60 °C (-40…140 °F)
ACCURACY TEMPERATURE AT 5…60 °C (41…140 °F) typ. ± 0.5 °C (± 0.9 °F)
OUTPUT ANALOGUE 0-5V / 10 V and 0/4-20 mA
OUTPUT DIGITAL Modbus RTU
SUPPLY 15-35 VDC (current)
  12-30 VDC (voltage / RS485)